EMAIL: sales@eseasongear.com

Milwaukee PH55 Waterproof pH/C/F Tester

Milwaukee PH55 Waterproof pH/C/F Tester
Milwaukee PH55 Waterproof pH/C/F Tester
Item# Mil-PH55_8oz
$64.00


User Manual

Milwaukee PH55 Waterproof pH/C/F Tester Meter, pH 55

Milwaukee Instruments Martini pH DUAL LEVEL LCD TESTER WITH AUTOMATIC TEMPERATURE COMPENSATION, 2 POINTS AUTOMATIC CALIBRATION, 0.1 pH ACCURACY; RANGE; -2.0 TO 16.0 pH.

pH/temperature Specifications: Range -2.00 to 16.00 pH, -5.0 to 60.0 C / 23.0 to 140 F Resolution 0.1 pH, 0.1 C / 0.1 F, Accuracy @ 20C 0.1 pH, 0.3 C/ 0.6 F, Calibration automatic, 1 or 2 points temperature compensation automatic Probe (included) pH/C (Mi56P) Auto off after 8 minutes of non-use Dimensions 200 x 38mm Weight 100 g

Accessories

Storage Solution for pH/ORP Electrodes, Small, 20ml
eSeasongear Storage Solution for pH & ORP Electrodes/Probes/Sensors, Small Size, 20ml

(HI 70300, HI70300, HI70300S, MA9015 MA9015S)
$2.96
Storage Solution for pH/ORP Electrodes, Small, 20ml ESG-Storage_20ml
Milwaukee MI56P Replacement pH/T Probe for PH55/PH56
Milwaukee Instruments MI56P pH Temp Probe

Replacement spare pH probe electrode sensor for PH55 PH56 pH digital pen tester meter, MI 56P

Martini MI56 56
$36.98
Milwaukee MI56P Replacement pH/T Probe for PH55/PH56 Mil-MI56P
Milwaukee PH55 + MA9015 + MA9004 + MA9007 Combo

User Manual

Milwaukee PH55 + MA9015 + MA9004 + MA9007 Meter/Solution Combo includes:

1. Milwaukee PH 55 waterproof pH tester

2. Milwaukee MA 9015 electrode storage solution, 230ml

3. Milwaukee MA 9004 pH 4 buffer solution, 230ml

4. Milwaukee MA 9007 pH 7 buffer solution, 230ml

5. Free priority shipping (Please do not select the Priority shipping!)
List: $105.00
Sale: $85.99
Milwaukee PH55 + MA9015 + MA9004 + MA9007 Combo Mil-PH55_MA9015_9004_9007
Milwaukee Instrum. Suggested Solutions for pH Meters / Controllers
Suggested Solutions for pH Meters / Controllers

1. MA9015 storage solution for pH probe storage.

2. MA9016 cleaning solution for pH probe cleaning.

3. MA9007 pH 7 buffer for 1-point pH calibration.

4. MA9004 pH 4 and MA9010 pH 10 for 2-point pH calibration.

After each use, always rinse the probe with water, clean it with MA9016 cleaning solution and store the probe with MA9015 storage solution.

For probe cleaning - Soak it in MA9016 cleaning solution for about 3 minutes once a day or at least once a week to prevent clogging and to maintain accuracy.

For probe storage - Place a sponge or tissue in the bottom of the cap, and pour some MA9015 storage solution into the cap.

Never let probe dry after conditioning and Never use distilled/deionized water for storage purposes.

Always rinse the pH electrode with water between calibrations and testings.

Check out the "pH Electrode Care" for more details.
Spare 1.5 V Battery for Pocket Tester, Pack/10
Spare 1.5 V Battery for HANNA, HM Digital and Milwaukee Pocket pH TDS ORP Testers, Pack/10

Replacement button battery batteries for Pen style Tester Meter
$2.99
Spare 1.5 V Battery for Pocket Tester, Pack/10 TQ-AG13-10X
sales@eseasongear.com - We accept credit cards via PayPal, no PayPal account is required